| Input |
Input Voltage Range |
3 Phase, 415V AC |
| Input Frequency Range |
47-63 Hz |
| Output |
Output Voltage Range |
3 phase, 415V AC (Same as input voltage) |
| Out Frequency Range |
0-600 Hz |
| External Interface |
Programmable Digital Input |
Six Channel inputs. One is the high-speed pulse input (HDI1). Another four channel inputs can be extended by optional I/O card |
| Programmable Analog Input |
AI1; 0~10V, AI2; 0~10V or 0~mA, optional I/O extension card can offer another two inputs; AI3; 10V~10V, AI4; 0~10V or 0~20mA. |
| Progrmmable Open Circuit Collector Output |
One channel output, I/O extension card can offer another one (Open circuit collector output or high-speed pulse output). |
| Relay Output |
Two channel outputs, optional I/O extension card can offer another one |
| Analog Output |
One Channel output, optional I/O extension card can offer another one, 0/4~20mA or 0/2~10V selectable. |
| Technology Features |
Control Mode |
Sensorless Vector Control, Vector Control with PG, V/f Control. |
| Overload Capacity |
150% rated current for 60 sec.200% rated current for 2 sec, (Vector control) |
| Starting Torque |
Sensorless Vector Control:0.5Hz / 150%, Vector Control : OHz/180% |
| Speed - Adjust Ration |
Sensorless Vector Control:1:100, Vector Control with PG:1:1000 |
| Speed Accuracy |
Sensorless Vector Control:±0.5% of maximum speed, Vector Control : ± 0.02% of maximum speed. |
| Carrier Frequency |
1.0KH~16.0 KHz. It can be adjusted automatically according to the features of temperature and load. |
| Function Features |
Frequency - Setting Mode : Digital Setting, Analog Setting, Pulse Frequency setting, Serial Communication Setting, Multi-Speed, Simple PLC Setting etc. The switch between the defining combination and the defining mode can be realized. |
| Torque-Control Function offers multimode torque setting. |
| PID Control Function offers precise process control |
| Simple PLC & Multi-segments Speed Control Function offers 16 segment speed Control. |
| Travers Control Function |
| Length and Time Control Function. |
| Non-Stop Function while instantaneous power failure. |
| Speed trance Function (Catch-on fly) offers smooth start of the running motor. |
| QUICK / JOG Function offers Multi-function shorcut key defined by user. |
| Automatic Voltage Adjust Function offers to maintain the output voltage constant automatically when mains voltage fluctuating. |
| Up to 29 functions for failure protection offers protection against Over current, over voltage, under voltage, over temperature, input / output phase failure, drive/motor load, IGBT failure, etc |