• Reaction time is counted by millisecond, the rotaitonal speed will be fixed in 3ms, and reaction time of the communication control function is 0.1ms.
• Open loop control:supply 160% torque in whole frequency range.
• When load changes : maintain the best stability, speedy torque compensate.
• High precision in slip compensation<0.5%
• High output scanning time <0.003ms
• Analog input scanning time <3ms
• Brand-new soft-switching technology:du/dt can be controlled by it validly, reduce the sudden changeof voltage and can be matched with other standard motors. The motor cable can be used 300m (un-shield) or 150m (shield).
HC1- V provides you many option components, this will make equipment characteristic more complete.
Terminal :
»
HC1-V Provides you many option components, this will make equipment characteristic mor complete
» 2 sets of DC reactor can restrain the producing of harmonic effectively and raise power element of inverters without extra power compensate equipment. <Optional> » RFI filter. <Optional> » Built-in standard two-string encoder input terminal. » Two standard series connection interface : one for Keypad and the other for RS485. » Provide many kinds of communication card for option. »Built-in PID control
»
LCP (Local Control Panel) make parameter setting easily.
» LCP can make a copy of parameter from one inverter to another freely and easily. » Outsize LCD will show you 4 kind of statistics at the same time.
»
Characteristics and Function
» Provide speed, torque and special electric machinery control mode.
» ASFM will regulate carrier frequency automatically, improve efficiency,reduce noise according to the load condition and permit manual control when running.
» AMA funtion measures crucial parameter in the static status, if the factory setting differs from the machinery, AMA function will ensure the performance of machinery torque to the best status. It can be used in the most sever application occasions.
Input/Output Characteristics
Mode HC1-
A
a
B
b
c
»
Input Voltage
220V±15%/400V±15%
»
V2015
700
680
242
200
260
»
Input Frequency
50/60HZ±1%
»
V2020
800
780
308
270
269
»
Output Voltage
0-100% iNPUT Voltage
»
V2025
»
Output Frequency
0-400HZ
»
V2030
740
720
242
180
260
»
Efficiency
>0.98
»
V2040
»
Overload
150%
»
V2050
*
800
*
370
375
Environmental Conditions
»
V4015
620
600
242
180
260
»
Ambient Temperature
Max.50°C
»
V4020
»
Storage Temperature
-25°C-70°C
»
V4025
740
720
242
180
260
»
Humidity
Under 95%
»
V4030
»
Altitude
1000m
»
V4040
840
820
308
210
296
»
Vibration
0.7G
»
V4050
»
Enclosures
IP20
»
V4060
I/O signal
»
V4075
840
820
370
240*
355
»
Digital Input
24V DC (Ri=24K)
»
V4100
»
Analog Input(Voltage)
0-±10V (Ri=10K)
»
V4125
1200*
1180*
420
280*
373(+44)*
»
Analog Input(Current)
0/4-20mA(Ri=200Ω)
»
V4150
»
DC Power Supply
24V,200mA
»
V4175
1590*
1540*
420
280
373(+44)*
»
Analog Output
0/4-20mA(Ri=500Ω)
»
V4215
»
Relay Output
220V AC, 2A/25V DC,1A