» AC Variable Frequency Drives :

 HC1-A   II  HC1-C  II  HC1-H  II  HC1-P  II  HC1-SV  II HC1-V
» Drive and PLC control Panels, Electrical motor contro Panel such as MCC,PMCC...........
» DC Drives
» Soft Starters
» Industiral automation solution: PLC,HMI,SCADA and Process Monitoring, PC based automation
» Engineering & Technical consultancy Services & Trading
AC drives, AC Victor drives, Inverter, drive, Victor AC drives, AC Variable Frequency Drives, AC Variable Drive, DC Drive, PLC Control Panels, Electrical Motor Contro Panel, MCC, PMCC, DC Drives, Ahmedabad, India

AC Drives - True Genius TG-600                                                                   Ac Drives - Victor G1000 & 2000
» Down
INTRODUCTION :

VICTOR is a Microcomputer controlled General Purpose AC Drive (Inverter) with state-of-the -art electronics and incorporates the lastest semiconductor power device - Insulated Gate Bipolar Transistors (IGBT) and unique display unit consisting of 4 seven segment LED's and 16 x 2 character LCD's. VICTOR AC Drives are available in VICTOR G1000 and VICTOR G2000 Series.

The control circuity is centered around a 6 bit Microcontroller. The control method used is Specae Vector Modulation (SVM) in VICTOR G1000 and Sinusoidal Pulse Width Modulation with Flux Control in VICTOR G2000, which optimises utillisation of input voltage and facilitates smooth rotation of the Motor al low speeds.

SELECTION CAHRT
VICTOR G1000 : 2.2 TO 22 kW
Parameter/ Model VTRO22G1 VTR037G1 VTR055G1 VTR075G1 VTR110G1 VTR150G1 VTR185G1 VTR220G1
Application Motor output (kW) 0.4~2.2 3.7 5.5 7.5 11.0 15.0 18.5 22.0
Inverter output at 415V (kVA) 4.0 6.5 9.0 13.0 17.0 21.0 28.0 32.0
Rate output current (Amps.) 5.5 9.0 13.0 18.0 24.0 30.0 39.0 45.0
Nett Weight (Kg) 9.0 12.0 12.0 12.5 17.5 19.0 20.5 20.5
Dimensions (Hx Wx D in mm) 364x208x290 660x418x300 660x418x370 860x578x360 900x750x360
VICTOR G2000 : 30 TO 160 kW
Parameter/ Model VTR030G2 VTR037G2 VTR045G2 VTR055G2 VTR075G2 VTR 110G2 VTR160G2
Applicable Motor output (kW) 30.0 37.0 45.0 55.0 75.0 110.0 160.0
Inverter output current (Amps.) 41.0 52.0 65.0 79.0 105.0 151.0 251.0
Rated output current (Amps.) 57.0 73.0 91.0 110.0 146.0 210.0 300.0
Nett Weight (kg)

30.0

47.0 47.0 49.0 90.0 95.0 120.0
Dimensions (Hx Wx D in mm) 610x318x290 660x418x300 660x418x370 860x578x360 900x750x360

FEATURES
» RAISE/ LOWER OPERATION
The output frequency setting can be increased or decreased through external potential free contacts. This feature eliminates the need of external reference units such as Satic reference unit, Motorised potentiometer.

» CURRENT LIMITING FUNCTION
VICTOR Drives are capable of limiting the output current to a pre-set level ensuring continuous operation of the Drive without tripping, espacially during acceleration.

» THREE WIRE OPERATION
This feature allows to control run or stop operation by means of one pulse command eliminating additioal external relay circuit.

» CATCH ON FLY
In high inertia loads, during power resumption after failure, Inverter will catch on from the frequency corresponding to the actual motor speed and accelerates to the reference speed.

» FAULT MEMORY
Upto 19 previous faults are stored on first out order and can be viewed in the same order. This facilitates ease of trouble shooting.
» DC INJECTION BRAKING
This function is used to decrease the stop time and to improve the stop position accuracy. The frequency at which DC injection braking starts, braking voltage and braking time can be programmed.

» EIGHT STOP SPEED CONTROL
Multi-step speed operation can be realised by turning on and off with three external potential free contacts and a miximum of eight different speeds can be programmed.

» ELECTRONIC THERMAL OVERLOAD RELAY

The Drive will trip considering the Motor cooling characteristics at low speed (inverse time characteristics).

» SLIP COMPENSATION
This function corrects the AC Drive output frequency based on load current to compensate the slip of the AC Motor and the resulting accurancy can be 1% of base speed.

»
MULTI ACCELERATION/DECELERATION TIME
This function enables to program four different acceleration or deceleration time realised through two digital inputs.

TECHNICAL SPECIFICATION                                                                                                                               » Up
Input Rating Power supply 3 Phase, 380V /415V /440V, 50 - 60Hz
Allowable variations Voltage : +10% -15%, Frequency : +/-5 %, Imbalance less than 3%
Output Rating Output Voltage Range 3 phase, 415V AC (Same as input voltage)
Out Frequency Range G1000 0.5 to 440 Hz
Frequency stability Digital setting : +/- 0.01% of max. frequency (-10ºC to +50ºC)
Analog setting ; +/- 0.2% of max.frequency (at 25ºC +/-10ºC)
Overload capacity 150% for one minute
Control Specification Control system G1000 Speace Vector Modulation G2000 SPWM with flux control
Frequency control range 0.5 to 440Hz 0.5 to 240Hz
Adjustable curent limit 30 to 180% of rated current 0 to 180% of rated current
Maximum frequency 40 -440Hz 40-240 Hz
Base frequency 40 -440Hz 40-240 Hz
Carrier frequency 2kHz fixed 2-5kHz
Gain for frequency setting Not applicable 50-200%
Starting frequency hold time Not applicable 0.01 to 5 seconds
Frequency setting signal filter Not applicable 0.01 to 5 seconds
Control Specification Frequency setting Key operation : Up /Down keys, Potentiometer 1 k ohm (1/2 W).
Analog input: 0 to 10V, 0 to -10V, 4-20mA, +10V to - 10V (polarity based speed reversal), Raise/ Lower Switch, 8 Preset frequencies with X1, X2 and X3 terminals.
Frequency resolution Digital : 0.01 Hz step (at Fmax. 50Hz.)
Analog : 0.05 Hz step ( at Fmax. 50 Hz.)
jump Frequency Jump frequency control (3 points) with adjustable jump rage
Acceleration / Decelerations Time 0.01 to 3600 seconds (4 independently adjustable acceleration and deceleration)
Brakig torque DC injection braking (frequency : 0.5 to 10 Hz, Time : 0 to 30 seconds, Voltage : 0 to 5%) Dynamic braking 20 to 150%
Slip compensation Available, Load current dependent.
Max./Min. frequency limit Frequency lower limit / Frequency upper limit (Fstart to Fmax.)
Fault history display Present fault and upto 19 previous faults
Starting frequency 0.5 - 10Hz
Protection Invertor Trip and Error messages Stall prevention, Auto restart during instantaneous power failure for 15 ms duration, Under voltage, Over voltage, Over current during acceleration / deceleration / steady state condition, THR fault, Heat sink overheating, Short circuit, inverter overload, Electronic thermal overload trip asnd Setting error.
Indication adn Control Analog/ Digital output G1000 Frequency G2000 Frequency/ Load meter
  External output 3 Programmable open coolector outputs and 1 Fault alarm replay output 3Programmable open collector outputs, 1 Programmable and 1 Fault alarm relay outputs
  Display unit having 16x2 character LCD with back-lit, 4 Seven segment LED adn 8 key touch pad Output frequency, RPM, Load current, and DC voltage Output frequency, Load current, RPM, DC voltage, Output voltage adn Output power
Environmental Conditions Installation location Indoor not more than 1000 mtrs. above sea level. Do not install in a dirty location or expose to corrosive gases or direct sun rays
Ambient temperature -10ºC to +40ºC (-10ºC to + 50ºC when mounted inside the switch board)
Humidity 90% RH or less ( non-condensing)
Cooling system Forced air cooling type
Optional Facilities RS 232C/ RS 485 (Serial communication facility), Dynamic Braking Facility with or without Resistor Unit, Outoput AC Reactor.