AC Drives - True Genius TG-600 Ac Drives - Victor G1000 & 2000
» Down |
INTRODUCTION :
VICTOR is a Microcomputer controlled General Purpose AC Drive (Inverter) with state-of-the -art electronics and incorporates the lastest semiconductor power device - Insulated Gate Bipolar Transistors (IGBT) and unique display unit consisting of 4 seven segment LED's and 16 x 2 character LCD's. VICTOR AC Drives are available in VICTOR G1000 and VICTOR G2000 Series.
The control circuity is centered around a 6 bit Microcontroller. The control method used is Specae Vector Modulation (SVM) in VICTOR G1000 and Sinusoidal Pulse Width Modulation with Flux Control in VICTOR G2000, which optimises utillisation of input voltage and facilitates smooth rotation of the Motor al low speeds.
|
SELECTION CAHRT
VICTOR G1000 : 2.2 TO 22 kW |
| Parameter/ Model |
VTRO22G1 |
VTR037G1 |
VTR055G1 |
VTR075G1 |
VTR110G1 |
VTR150G1 |
VTR185G1 |
VTR220G1 |
| Application Motor output (kW) |
0.4~2.2 |
3.7 |
5.5 |
7.5 |
11.0 |
15.0 |
18.5 |
22.0 |
| Inverter output at 415V (kVA) |
4.0 |
6.5 |
9.0 |
13.0 |
17.0 |
21.0 |
28.0 |
32.0 |
| Rate output current (Amps.) |
5.5 |
9.0 |
13.0 |
18.0 |
24.0 |
30.0 |
39.0 |
45.0 |
| Nett Weight (Kg) |
9.0 |
12.0 |
12.0 |
12.5 |
17.5 |
19.0 |
20.5 |
20.5 |
| Dimensions (Hx Wx D in mm) |
364x208x290 |
660x418x300 |
660x418x370 |
860x578x360 |
900x750x360 |
| VICTOR G2000 : 30 TO 160 kW |
| Parameter/ Model |
VTR030G2 |
VTR037G2 |
VTR045G2 |
VTR055G2 |
VTR075G2 |
VTR 110G2 |
VTR160G2 |
| Applicable Motor output (kW) |
30.0 |
37.0 |
45.0 |
55.0 |
75.0 |
110.0 |
160.0 |
| Inverter output current (Amps.) |
41.0 |
52.0 |
65.0 |
79.0 |
105.0 |
151.0 |
251.0 |
| Rated output current (Amps.) |
57.0 |
73.0 |
91.0 |
110.0 |
146.0 |
210.0 |
300.0 |
| Nett Weight (kg) |
30.0 |
47.0 |
47.0 |
49.0 |
90.0 |
95.0 |
120.0 |
| Dimensions (Hx Wx D in mm) |
610x318x290 |
660x418x300 |
660x418x370 |
860x578x360 |
900x750x360 |
|
FEATURES
» RAISE/ LOWER OPERATION
The output frequency setting can be increased or decreased through external potential free contacts. This feature eliminates the need of external reference units such as Satic reference unit, Motorised potentiometer.
» CURRENT LIMITING FUNCTION
VICTOR Drives are capable of limiting the output current to a pre-set level ensuring continuous operation of the Drive without tripping, espacially during acceleration.
» THREE WIRE OPERATION
This feature allows to control run or stop operation by means of one pulse command eliminating additioal external relay circuit.
» CATCH ON FLY
In high inertia loads, during power resumption after failure, Inverter will catch on from the frequency corresponding to the actual motor speed and accelerates to the reference speed.
» FAULT MEMORY
Upto 19 previous faults are stored on first out order and can be viewed in the same order. This facilitates ease of trouble shooting. |
» DC INJECTION BRAKING
This function is used to decrease the stop time and to improve the stop position accuracy. The frequency at which DC injection braking starts, braking voltage and braking time can be programmed.
» EIGHT STOP SPEED CONTROL
Multi-step speed operation can be realised by turning on and off with three external potential free contacts and a miximum of eight different speeds can be programmed.
» ELECTRONIC THERMAL OVERLOAD RELAY
The Drive will trip considering the Motor cooling characteristics at low speed (inverse time characteristics).
» SLIP COMPENSATION
This function corrects the AC Drive output frequency based on load current to compensate the slip of the AC Motor and the resulting accurancy can be 1% of base speed.
» MULTI ACCELERATION/DECELERATION TIME
This function enables to program four different acceleration or deceleration time realised through two digital inputs.
|
TECHNICAL SPECIFICATION » Up
| Input Rating |
Power supply |
3 Phase, 380V /415V /440V, 50 - 60Hz |
| Allowable variations |
Voltage : +10% -15%, Frequency : +/-5 %, Imbalance less than 3% |
| Output Rating |
Output Voltage Range |
3 phase, 415V AC (Same as input voltage) |
| Out Frequency Range |
G1000 0.5 to 440 Hz |
| Frequency stability |
Digital setting : +/- 0.01% of max. frequency (-10ºC to +50ºC)
Analog setting ; +/- 0.2% of max.frequency (at 25ºC +/-10ºC) |
| Overload capacity |
150% for one minute |
| Control Specification |
Control system |
G1000 |
Speace Vector Modulation |
G2000 |
SPWM with flux control |
| Frequency control range |
0.5 to 440Hz |
0.5 to 240Hz |
| Adjustable curent limit |
30 to 180% of rated current |
0 to 180% of rated current |
| Maximum frequency |
40 -440Hz |
40-240 Hz |
| Base frequency |
40 -440Hz |
40-240 Hz |
| Carrier frequency |
2kHz fixed |
2-5kHz |
| Gain for frequency setting |
Not applicable |
50-200% |
| Starting frequency hold time |
Not applicable |
0.01 to 5 seconds |
| Frequency setting signal filter |
Not applicable |
0.01 to 5 seconds |
| Control Specification |
Frequency setting |
Key operation : Up /Down keys, Potentiometer 1 k ohm (1/2 W).
Analog input: 0 to 10V, 0 to -10V, 4-20mA, +10V to - 10V (polarity based speed reversal), Raise/ Lower Switch, 8 Preset frequencies with X1, X2 and X3 terminals. |
| Frequency resolution |
Digital : 0.01 Hz step (at Fmax. 50Hz.)
Analog : 0.05 Hz step ( at Fmax. 50 Hz.) |
| jump Frequency |
Jump frequency control (3 points) with adjustable jump rage |
| Acceleration / Decelerations Time |
0.01 to 3600 seconds (4 independently adjustable acceleration and deceleration) |
| Brakig torque |
DC injection braking (frequency : 0.5 to 10 Hz, Time : 0 to 30 seconds, Voltage : 0 to 5%) Dynamic braking 20 to 150% |
| Slip compensation |
Available, Load current dependent. |
| Max./Min. frequency limit |
Frequency lower limit / Frequency upper limit (Fstart to Fmax.) |
| Fault history display |
Present fault and upto 19 previous faults |
| Starting frequency |
0.5 - 10Hz |
| Protection |
Invertor Trip and Error messages |
Stall prevention, Auto restart during instantaneous power failure for 15 ms duration, Under voltage, Over voltage, Over current during acceleration / deceleration / steady state condition, THR fault, Heat sink overheating, Short circuit, inverter overload, Electronic thermal overload trip asnd Setting error. |
| Indication adn Control |
Analog/ Digital output |
G1000 |
Frequency |
G2000 |
Frequency/ Load meter |
| |
External output |
3 Programmable open coolector outputs and 1 Fault alarm replay output |
3Programmable open collector outputs, 1 Programmable and 1 Fault alarm relay outputs |
| |
Display unit having 16x2 character LCD with back-lit, 4 Seven segment LED adn 8 key touch pad |
Output frequency, RPM, Load current, and DC voltage |
Output frequency, Load current, RPM, DC voltage, Output voltage adn Output power |
| Environmental Conditions |
Installation location |
Indoor not more than 1000 mtrs. above sea level. Do not install in a dirty location or expose to corrosive gases or direct sun rays |
| Ambient temperature |
-10ºC to +40ºC (-10ºC to + 50ºC when mounted inside the switch board) |
| Humidity |
90% RH or less ( non-condensing) |
| Cooling system |
Forced air cooling type |
| Optional Facilities |
RS 232C/ RS 485 (Serial communication facility), Dynamic Braking Facility with or without Resistor Unit, Outoput AC Reactor. |
|